Sign in →

Test Code LAB10262 Adaptive clonoSEQ MRD

Important Note

Clonality (ID) must also be performed in a separate order to determine disease burden on an initial specimen.

Methodology

The clonoSEQ Assay is an in vitro diagnostic that uses multiplex polymerase chain reaction
(PCR) and next-generation sequencing (NGS)

Performing Laboratory

Adaptive Biotechnologies

Specimen Requirements

  • Blood
    • If DLBCL MRD:
      • 2 x10mL Streck tubes- clonoSEQ ctDNA Kit
      • Green box collection kit
      • Do not refrigerate or freeze streck tubes
    • If ALL, CLL or MM: 
      • >2mL in 1 EDTA tube-clonoSEQ FRESH Kit
      • Blue box collection kit
  • Bone marrow
    • 1mL  bone marrow aspirate in EDTA

 

  • Please note: blood samples should be collected in the corresponding Adaptive kit and sent to RMH Send Out laboratory for processsing. 
    • To obtain a kit for an order in Epic, please call RMH Send Outs at 614-566-3715. 
  • Please collect Mon-Fri only

Specimen Transport Temperature

Specimen Type Stability
Blood EDTA tube 4 days ambient, 7 days refrigerated
Blood Streck tubes 5 days ambient. 
Bone marrow EDTA 4 days ambient, 7 days refrigerated

 

Reference Values

Please refer to patient's report. 

Day(s) Test Set Up

Mon - Fri