Test Code LAB1197 Syphilis Antibody, (Treponema Assay), Serum
Reporting Title
Syphilis Ab, S
Methodology
Testing Algorithm:
If syphilis test is positive, the RPR test is performed automatically as a reflex test followed with a titer if the RPR is positive.
If RPR is negative a T.Pallidum antibody by FTA-ABS or TP-PA will be performed.
Method Name:DiaSorin LIAISON®, Chemiluminescence Assay
Performing Laboratory
OhioHealth Laboratory Services-RMH Special Testing
Specimen Requirements
Preferred:
Specimen Type: Draw blood in a gold-top serum gel tube(s). Spin down and send 1.0 mL refrigerated
Also Acceptable:
A speckled-top serum gel tube (s) or a plain, red-top tube(s) is also acceptable.
Specimen Minimum Volume: 0.4 mL
Reject Due To:
Hemolysis: Mild OK; Gross reject
Lipemia: Mild OK; Gross reject
Icterus: NA
Other: NA
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum | Refrigerated | 7 days |
Frozen | Stable |
Specimen Transport Temperature
Refrigerated (preferred) OK/FrozenOK
Reference Values
Negative
Day(s) Test Set Up
Monday through Friday 24/7
Saturday and Sunday day shift only
Test Classification and CPT Coding
CPT Code:
86780