Test Code LAB29 Lithium, Serum

Reporting Title

Lithium

Methodology

 

Roche Diagnostics, ISE: RMH, BH, DH, DMH, GCMH, GMC, GMH, MGH, MH, OBH, PMH, WECC Core Laboratories

 

Performing Laboratory

OhioHealth Laboratory Services - RMH, BH, DH, DMH, GCMH, GMC, GMH, MGH, MH, OBH, PMH, WECC Core Laboratories

Specimen Requirements

Draw blood in a gold-top or a speckled-top serum gel tube(s). (Green-top [heparin] tube or lavender-top [EDTA] tube is not acceptable.) Spin down and send 1 mL of serum refrigerated. Serum for a trough level should be drawn 15 minutes prior to next oral dose. Serum for a peak level should be drawn 3 hours post oral dose.

Note:  Plain, red-top tube(s) is also acceptable.

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated 7 days
  Ambient  1 day
  Frozen  6 months

 

 

Specimen Transport Temperature

Refrigerate: OK

Ambient: OK

Frozen: NO

Reference Values

Therapeutic concentration:  0.6-1.2 mmol/L

Toxic concentration:  >1.5 mmol/L

Critical value  >1.5 mmol/L

Alerting category: Always called within 1 hour

 

Day(s) Test Set Up

Monday through Sunday; Continuously

Test Classification and CPT Coding

80178