Test Code LAB344 Autoantibodies to Ro52/Ro60/SS-A/Autoantibodies toSS-B/La, Serum.
Reporting Title
Ro52, Ro60, SSB
Methodology
BIO-FLASH Chemiluminescent Immunoassay
Useful for evaluation of patients with Sjögren’s syndrome and systemic lupus erythematous.
Performing Laboratory
OhioHealth Laboratory Services-RMH Special Testing
Specimen Requirements
Draw blood in a gold-top serum gel tube(s). (Microbially contaminated or heat-treated specimens are not acceptable.) Spin down and send 1 mL of serum refrigerated. Sample is stable refrigerated for 14 days
Note: A speckled-top serum gel tube (s) or a plain, red-top tube(s) is also acceptable.
Specimen Transport Temperature
Refrigerate: OK
Frozen: OK
Reference Values
Negative: <20 CU
Positive: ≥20 CU
Day(s) Test Set Up
Monday through Friday day shift only
Test Classification and CPT Coding
86235 x 3