Test Code LAB47 Ammonia, Plasma
Reporting Title
Ammonia
Methodology
Roche Diagnostics: RMH, BH, DH, DHC, DMH, GCMH, GMC, GMH, MGH, MH, OBH, PMH, WECC, HMH, SH
Ammonia is elevated in severe liver diseases such as cirrhosis, hepatitis, and Reye’s syndrome.
Performing Laboratory
OhioHealth Laboratory Services - RMH, BH, DH, DHC, DMH, GCMH, GMC, GMH, HMH, MGH, MH, OBH, PMH, SH, WECC Core Laboratories
Specimen Requirements
INPATIENT: Draw blood in a lavender-top (EDTA) tube(s) and send to the lab within 30 minutes on ice.
OUTPATIENT: Draw blood in a lavender-top (EDTA) tube (s) and place on ice. Centrifuge within 30 minutes of draw and send 1 mL of EDTA plasma frozen in plastic vial. Avoid hemolysis.
Sample Stability Information:
Separated plasma 3 hours refrigerated in a stoppered container at RMH, GMC, DH, DMH, GCMH, WECC, and DMH
Freeze specimen for longer storage or shipment
Specimen Transport Temperature
Frozen: OK
Refrigerate: NO
Ambient: NO
Reference Values
0-10 days: 100-200 Micromol/L
11 days-2 years: 40-80 Micromol/L
≥3 years: 12-47 Micromol/L
Day(s) Test Set Up
Monday through Sunday- Continuously
Test Classification and CPT Coding
82140