Sign in →

Test Code LAB503 Culture, Wound, Aerobic

Additional Codes

44060

44189

44022

44218

44235

44239

Reporting Title

Wound Aerobic Culture

Methodology

Includes Gram stain, aerobic identification, and susceptibilities when appropriate.

Performing Laboratory

OhioHealth Laboratory Services-RMH Microbiology

Specimen Requirements

Submit only 1 of the following specimens:

 

Non-Swab Specimen

1. Collect specimen from affected area and place in a screw-capped, sterile container.

2. Label container with patient’s name (first and last), MR# or DOB, date and actual time of collection, and type of specimen.

3. Maintain sterility and forward promptly at ambient temperature only.

Note:  Specimen source is required on request form for processing.

 

Swab Specimen

 

1.Collect the specimen from the affected area using the swab provided in the BD ESwab Collection and Transport System. Be sure not to touch below the red breakpoint line to avoid contamination.

2. Aseptically unscrew and remove the cap from the tube.

3. Insert the swab into the tube and bend the swab shaft at the breakpoint indicated by the red line marked on the swab shaft against the tube to break the shaft. Discard the broken handle part of the swab shaft.

4. Replace the cap on the tube and secure it tightly.

5. Label tube with patient’s name (first and last), MR# or DOB,  date and actual time of collection, and type of specimen.

6. Maintain sterility and forward promptly at ambient temperature only.

Note:  Specimen source is required on request form for processing.

            ESwabs are acceptable up to 48 hours after collection

Specimen Transport Temperature

Ambient/Refrigerate NO/Frozen NO

Reference Values

No growth after 48 hours

Day(s) Test Set Up

Monday through Sunday

Test Classification and CPT Coding

87070 - culture

87205 - Gram stain

87077 - identification (if appropriate)

87186 - susceptibility (if appropriate)

87181 - susceptibility, E Test, each antibiotic, (if appropriate)

87147 - serotyping, each (if appropriate)

87185 - enzyme detection (if appropriate)