Sign in →

Test Code LAB57 Carcinoembryonic Antigen (CEA), Serum

Reporting Title

CEA

Methodology

Roche Diagnostics Electrochemiluminescence Immunoassay

Results from assays produced by different manufacturers may not be comparable

 

Useful For

Used in cancer patient prognosis, status, assessment, and monitoring.

Performing Laboratory

OhioHealth Laboratory Services-RMH Special Testing and MH Core Laboratories

Specimen Requirements

Prefer: Serum

Draw blood in a gold-top serum gel tube(s). (Hemolyzed specimen is not acceptable.) Spin down and send 1 mL of serum refrigerated. Sample is stable refrigerated for 14 days

Also acceptable:

A speckled-top serum gel tube (s) or a plain, red-top tube(s) is also acceptable.

 

Heterophile antibodies may interfere with this assay. 

 

Collection Instructions:

1. Serum gel tubes should be centrifuged within 2 hours of collection.

2. Red-top tubes should be centrifuged and aliquoted within 2 hours of collection.

 

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated 7 days
  Ambient   
  Frozen  6 months

 

Specimen Transport Temperature

Refrigerate/Frozen OK/Ambient OK

Reference Values

Riverside Special Testing

0-2.5 ng/mL (nonsmoker)

0-5.0 ng/mL (smoker)

Serum markers are not specific for malignancy, and values may vary by method. Values seen in malignant and non-malignant conditions overlap considerably, ruling out the use of CEA as a screen for malignancy. CEA is elevated in a variety of malignant conditions as well as collagen vascular disease, infarction, infections, inflammatory lesion, renal impairment, smoking, and trauma.

Day(s) Test Set Up

Monday through Friday Continuous

Saturday and Sunday Day shift only

Test Classification and CPT Coding

82378