Test Code LAB714 Ethylene Glycol, Plasma or Serum

Important Note

Prefer the unopenned original collection tube be sent for testing.  

Reporting Title

Ethylene Glycol, Plasma or Serum

Methodology

Gas-Liquid Chromatography (GLC)

Performing Laboratory

University Reference Laboratories, Inc., Columbus

Specimen Requirements

Submit 1 of the following specimens:

 

Preferred:

 

Prefer the unopenned original collection tube be sent for testing.  

 

 

Serum

Draw blood in a plain, red-top tube(s). (Serum gel tube is not acceptable.) Centrifuge plain red-top tube(s), pipet off serum and send 2 mL (minimum volume:  0.3 mL) refrigerated if the original collection tube is not available.    

Note:  1. Always sent as “STAT” to the reference laboratory.

2. Indicate serum on request form.
3. Label specimen appropriately (serum).

 

Alternate:

Alternate:

Plasma

Draw blood in a lavender-top (EDTA) tube(s). Separate immediately from cells, aliquot plasma and store at refrigertated temperature 2-8°C. Send 2 mL (minimum volume:  0.3 mL) of EDTA plasma.

Note:  1. Always sent as “STAT” to the reference laboratory

2. Indicate blood on request form.
3. Label specimen appropriately (blood).

Specimen Transport Temperature

Ambient: No

Refrigerate: OK

Frozen: No

Reference Values

None detected

Critical value >10 mg/L

Alerting category: First instance called within 1 hour

Note:  Tests sent out to University Reference Laboratory, call within 1 hour of receipt in the reference laboratory.

Day(s) Test Set Up

Monday through Sunday

Test Classification and CPT Coding

82693