Sign in →

Test Code LAB797 Hepatitis A Antibody, Total (IgG and IgM), with Reflex to Hepatitis A, IgM

Infectious

Reporting Title

Hepatitis A

Methodology

Roche Diagnostics Electrochemiluminescence Immunoassay

Note:  1. Combined assay—this test detects IgG and IgM antibodies, but does not distinguish them.

2. If total antibody is reactive, hepatitis A IgM will be performed at an additional charge.

Performing Laboratory

OhioHealth Laboratory Services-RMH Special Testing

Specimen Requirements

 

Draw blood in a gold-top serum gel tube(s). Spin down and send 1 mL of serum refrigerated.  A speckled-top serum gel tube (s) or a plain, red-top tube(s) is also acceptable.

Alternate:

Plasma from  K2 EDTA  and Lithium Heparin is acceptable

 

Specimen Stability Information

Specimen Type Temperature Time
Serum/Plasma Refrigerated 14 days
  Ambient  6 days
  Frozen  3 months

 

Specimen Transport Temperature

Refrigerate: OK

Ambient: OK

Frozen: OK

Reference Values

Negative

Hepatitis A total antibody is indicative of past exposure to hepatitis A and may persist for years. Hepatitis A IgM antibody indicates recent or current infection.

Day(s) Test Set Up

Monday through Friday: 24/7

Saturday and Sunday: Day shift

 

Test Classification and CPT Coding

86708 - total antibody

86709 - IgM (if appropriate)