Test Code LAB846 Activated Protein C Resistance V (APCRV), Plasma
Additional Codes
Mayo Test ID |
---|
APCRV |
45568
Reporting Name
Activated Protein Resistance V, PUseful For
Evaluation of patients with incident or recurrent venous thromboembolism (VTE)
Evaluation of individuals with a family history of VTE
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Plasma Na CitOrdering Guidance
Although this assay can be performed in the absence of other coagulation tests and clinical information, it is most reliably performed as part of a consultative coagulation test panel with interpretive reporting (including appropriate testing of the same specimen to evaluate for the presence or absence of coagulation abnormalities or conditions that may affect interpretation of the APC resistance assay). This test is included among a panel of tests designated AATHR / Thrombophilia Profile, Plasma and Whole Blood.
Necessary Information
If a priority specimen, mark request form, give reason, and request a call-back.
Specimen Required
Specimen Type: Platelet-poor plasma
Collection Container/Tube: Light-blue top (3.2% sodium citrate)
Submission Container/Tube: Polypropylene vial
Specimen Volume: 1 mL
Collection Instructions:
1. For complete instructions, see Coagulation Guidelines for Specimen Handling and Processing.
2. Centrifuge, transfer all plasma into a vial, and centrifuge plasma again.
3. Aliquot plasma into a vial leaving 0.25 mL in the bottom of centrifuged vial.
4. Freeze plasma immediately (no longer than 4 hours after collection) at -20° C or, ideally at-40° C or below.
Additional Information:
1. Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
2. If priority specimen, mark request form, give reason, and request a call-back.
3. Each coagulation assay requested should have its own vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Na Cit | Frozen | 14 days |
Special Instructions
Reference Values
APCRV RATIO
≥2.3
Pediatric reference range has neither been established nor is available in scientific literature. The adult reference range likely would be applicable to children older than 6 months.
Day(s) Performed
Monday through Friday
Test Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
85307
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
APCRV | Activated Protein Resistance V, P | 13590-5 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
APCR | APCRV Ratio | 13590-5 |
INT55 | Interpretation | 48591-2 |
Report Available
1 to 3 daysMethod Name
Optical Clot-Based
Forms
If not ordering electronically, complete, print, and send a Coagulation Test Request (T753) with the specimen.