Sign in →

Test Code LAB852 Extractable Nuclear Antigen Antibodies, Serum

Reporting Title

ENA Screen 7

Methodology

Reflex Tests:
Unit Codes  Published Name Available Separately
     

  LAB2001

Autoantibodies to Sm/Autoantibodies to RNP

Yes 
 LAB344 Autoantibodies to Ro56/Ro60/SS-A/Autoantibodies to SS-B/La Yes
 LAB771 Autoantibodies to Scl 70 Yes
LAB770 Autoantibodies to Jo 1 Yes

 

 

 

 

 

 

 

 

 

 

 

Testing Algorithm:

If antibodies to extractable nuclear antigens (ENA) are positive, Jo 1, Scl 70, Sm/RNP, Ro52, Ro60 and SS-B/La are performed.

Method Name:

BIO-FLASH Chemiluminescent Immunoassay

General Information:

Identification of antibodies to ENA is useful in detection, diagnosis, and differentiation of connective tissue diseases, such as systemic lupus erythematosus and Sjögren’s syndrome.

Performing Laboratory

OhioHealth Laboratory Services-RMH Special Testing

Specimen Requirements

Draw blood in a gold-top serum gel tube(s). (Hemolyzed, icteric, microbially contaminated or heat-treated specimens are not acceptable). Spin down and send 1 mL of serum refrigerated. Sample is stable refrigerated for 7 days

Note:  A speckled-top serum gel tube (s) or a plain, red-top tube(s) is also acceptable.

Specimen Transport Temperature

Refrigerate: OK

Frozen: OK 

Reference Values

Negative

Day(s) Test Set Up

Monday through Friday day shift only

Test Classification and CPT Coding

86235 - screen, negative result