Sign in →

Test Code LAB90131 StaClot (Lupus Anticoagulant)

Reporting Title

StaClot (Lupus Anticoagulant)

Methodology

End point Clot Measurement

Includes PTT-LA. PTT-LA Mix and StaClot-LA

Used for the qualitative diagnostic determination of lupus anticoagulants in patient plasma in conjunction with the Dilute Russell Viper Venom Time.

Performing Laboratory

OhioHealth Laboratory Services-RMH Core Coagulation

Specimen Requirements

Submit only 1 of the following specimens:

 

Riverside Inpatients or Riverside Campus draw sites:

Testing must be performed within 4 hours of draw if submitting unprocessed whole blood.

 

Draw a full, light blue-top (citrate) tube; and send citrated whole blood. Invert several times to mix blood. Forward unprocessed whole blood promptly at ambient temperature only. Do not refrigerate. 

Note:

1. This assay requires its own specimen.

2. Gross hemolysis, icterus, and lipemia may affect results.

3. Indicate whole blood on request form.

4. Label specimen appropriately (whole blood).

 

Outpatients/Outreach Clients

Plasma-Frozen

Draw a full, light blue-top (citrate) tube. Spin down, remove plasma, spin plasma again, and place 1 mL of citrated platelet-poor plasma in 2 plastic vials. (Glass vial is not acceptable.) Pour-off vial should be no more than 2/3 full. Send specimen frozen.

Note:

1. This assay requires its own specimen.

2. Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious

    results.

3. Gross hemolysis, icterus, and lipemia may affect results.

4. Indicate plasma on request form.

5. Label specimen appropriately (plasma).

Specimen Transport Temperature

Ambient/Refrigerate NO/Frozen NO-Blood

Frozen/Refrigerate NO/Ambient NO-Plasma

Reference Values

PTT-LA            31.4-43.4 seconds

PTT-LA Mix      31.4-43.4 seconds

StaClot LA       0-7.9

 

An interpretive comment will default based on the results.

Day(s) Test Set Up

Tuesday and Friday