Test Code LAB90245 Lacosamide, Serum
Additional Codes
LACO
48454
Useful For
Monitoring serum concentrations of lacosamide to ensure compliance and appropriate dosing in specific clinical conditions (ie, severe kidney impairment, mild-to-moderate hepatic impairment, and kidney failure)
Reporting Name
Lacosamide, SSpecimen Type
SerumSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Collect specimen immediately before next scheduled dose.
2. For sustained-release formulations ONLY, collect specimen a minimum of 12 hours after last dose.
3. Centrifuge and aliquot serum into plastic vial within 2 hours of collection.
Specimen Minimum Volume
0.2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |
Reference Values
Patients receiving therapeutic doses usually have lacosamide concentrations of 1.0 to 10.0 mcg/mL.
Day(s) Performed
Monday through Saturday
Report Available
Same day/1 to 4 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
80235
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
LACO | Lacosamide, S | 59297-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
62772 | Lacosamide, S | 59297-2 |
Method Name
Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
Portions of this test are covered by patents held by Quest Diagnostics
Forms
If not ordering electronically, complete, print, and send one of the following with the specimen:
-Neurology Specialty Testing Client Test Request (T732)
-Therapeutics Test Request (T831)