Test Code LAB90253 Myeloperoxidase Antibodies, IgG, Serum
Reporting Title
Myeloperoxidase Ab, IgG, S
Methodology
Bio-Flash Chemiluminscent Immunoassay
Useful for: Evaluation of patients suspected og having immune-mediated vasculitis, especially microscopic polyangiitis (MPA), when used in conjunction with other autoantibody tests.
May be useful to follow treatment response or to monitor disease activity in patients with MPA.
Performing Laboratory
OhioHealth Laboratory Services- RMH Special Testing
Specimen Requirements
Preferred: Serum
Acceptable: Speckle top and plain red top tubes
Draw blood in gold top tube(s). Spin down and send 1 ml of serum refrigerated.
Note: hemolyzed, lipemic and/or icteric specimens are not acceptable.
Specimen Stability
Specimen Type |
Temperature |
Time |
Serum |
Refrigerated (preferred) |
7 days |
|
Frozen |
21 days |
Reference Values
Negative: < 20 CU
Positive: ≥ 20 CU
Day(s) Performed
Monday through Friday day shift only
Specimen Transport Requirements
Refrigerate: OK
Frozen: OK
Test Classification and CPT Coding
83516