Sign in →

Test Code LAB90373 Culture, Sputum Legionella pneumophila

Additional Codes

44267

Reporting Title

Sputum Legionella Culture

Methodology

Direct Fluorescent Antibody (DFA)/Conventional Culture with Fluorescent Antibody Stain for Identification of Positive Cultures

Performing Laboratory

OhioHealth Laboratory Services-RMH Microbiology

Specimen Requirements

Acceptable Specimens:

Induced sputum, sputum

 

1. Collect specimen and place in a screw-capped, sterile container.

2. Label container with patient’s name (first and last), MR# or DOB, date, actual time of collection and type of specimen.

3. Send specimen refrigerated. Maintain sterility and forward promptly.

Note:  Specimen source is required on request form for processing.

Specimen Transport Temperature

Refrigerate/Ambient NO/Frozen NO

Reference Values

CULTURE

No Legionella isolated

SMEAR

No organisms seen

Day(s) Test Set Up

Monday through Sunday

Test Classification and CPT Coding

87081 - culture

87278 - DFA