Test Code LAB90431 Very Low-Density Lipoprotein (VLDL), Plasma or Serum
Additional Codes
46925
Reporting Title
VLDL, Triglyceride
Methodology
Roche Diagnostics Enzymatic Colorimetric
Includes triglyceride and calculated VLDL.
Performing Laboratory
OhioHealth Laboratory Services- RMH , DH Core Laboratories
Specimen Requirements
Submit only 1 of the following specimens:
Preferred:
Serum
Draw blood in a gold-top serum gel tube(s) following an
overnight (12-14 hour) fast. Spin down and send 1 mL of serum
refrigerated.
Note:
1. A speckled-top serum gel tube (s) or a plain, red-top tube(s) is also acceptable.
2. Indicate serum on request form.
3. Label specimen appropriately (serum).
Alternate:
Plasma
Draw blood in a mint green-top (heparin) gel tube(s) following an overnight (12-14 hour) fast. Spin down and send 1 mL of heparinized plasma refrigerated.
Note: 1. Indicate plasma on request form.
2. Label specimen appropriately (plasma).
Specimen Transport Temperature
Refrigerate/Ambient OK/Frozen OK
Reference Values
TRIGLYCERIDE
National Cholesterol Education Program (NCEP) guidelines
Normal: <150 mg/dL
Borderline high: 150-199 mg/dL
High: 200-499 mg/dL
Very high: ≥500 mg/dL
VLDL
Males
20 years: 0-25 mg/dL
20-29 years: 0-30 mg/dL
30-39 years: 0-45 mg/dL
40-49 years: 0-40 mg/dL
50-59 years: 0-50 mg/dL
60-69 years: 0-40 mg/dL
>70 years: 0-30 mg/dL
Females
20 years: 0-20 mg/dL
20-29 years: 0-25 mg/dL
30-49 years: 0-30 mg/dL
50-59 years: 0-40 mg/dL
60-69 years: 0-35 mg/dL
>70 years: 0-30 mg/dL
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
84478