Test Code LAB90456 TORCH IgG Antibody Panel
Additional Codes
46587
Reporting Title
TORCH Panel (IgG)
Methodology
Profile Information: | ||
Unit Codes | Published Name | Available Separately |
LAB467 | Cytomegalovirus (CMV) Antibody, IgG | Yes |
LAB507 | Herpes Simplex Virus (HSV), IgG, Type 1 and Type 2 Specific Antibodies | Yes |
LAB496 | Rubella Antibody, IgG | Yes |
LAB501 | Toxoplasma gondii Antibody, IgG | Yes |
Performing Laboratory
OhioHealth Laboratory Services-RMH Special Testing
Specimen Requirements
Draw blood in a gold-top serum gel tube(s). (Contaminated, hemolyzed, or icteric specimen is not acceptable.) Spin down and send 2 mL (pediatric volume: 1 mL) of serum refrigerated.
Note:
1. A speckled-top serum gel tube (s) or a plain, red-top tube(s) is also acceptable.
2. Heterophile antibodies may interfere with this assay.
Specimen Transport Temperature
Refrigerate/Ambient NO/Frozen OK
Reference Values
See individual test listings.
Day(s) Test Set Up
Toxoplasma gondii Ab, IgG; CMV Ab, IgG; and HSV Ab, IgG Type 1 and 2 - Monday through Friday Continuous and Saturday and Sunday Day shift only
Rubella Ab, IgG - Monday through Friday.
Test Classification and CPT Coding
86644 - CMV antibody, IgG
86695 - HSV type 1
86696 - HSV type 2
86762 - rubella antibodies, IgG
86777 - Toxoplasma gondii antibody, IgG