Test Code LAB91992 Platelet Transmission Electron Microscopic Study, Whole Blood
Additional Codes
PTEM
Useful For
Diagnosing platelet disorders
Special Instructions
Method Name
Transmission Electron Microscopy
Reporting Name
Platelet TEM, BSpecimen Type
Whole Blood ACDShipping Instructions
Send specimen Monday through Wednesday.
Specimens must be received in testing laboratory within 72 hours of collection. Ship specimen overnight in an Ambient Shipping Box-Critical Specimens Only (T668) following the instructions in the mailer.
Necessary Information
Platelet Esoteric Testing Patient Information is required. Testing may proceed without the patient information, however, the information aids in providing a more thorough interpretation. Ordering providers are strongly encouraged to fill out the form and send with the specimen.
Specimen Required
Patient Preparation: Fasting is preferred but not required.
Supplies: Ambient Shipping Box-Critical Specimens Only (T668)
Collection Container/Tube:
Preferred: Yellow top (ACD, solution B)
Acceptable: Yellow top (ACD, solution A)
Specimen Volume: 6 mL
Collection Instructions: Send whole blood specimen in original tube. Do not aliquot.
Specimen Minimum Volume
3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Whole Blood ACD | Ambient | 72 hours |
Reference Values
Mean dense granules/platelet: ≥1.2
Day(s) Performed
Monday through Friday
Report Available
10 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
85390
88348
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
PTEM | Platelet TEM, B | 79768-8 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
CK109 | Platelet TEM | 79768-8 |
CK110 | Interpretation | 59466-3 |
Forms
1. Platelet Esoteric Testing Patient Information is required.
2. If not ordering electronically, complete, print, and send a Coagulation Test Request (T753) with the specimen.