Sign in →

Test Code LAB93008 Fentanyl Screen, Random, Urine

Additional Codes

FENS

Useful For

Screening for drug abuse or use involving fentanyl

Reporting Name

Fentanyl Screen, U

Specimen Type

Urine


Ordering Guidance


For situations where chain of custody is required, a Chain of Custody Kit (T282) is available. For chain-of-custody testing, order FENTX / Fentanyl with Metabolite Confirmation, Chain of Custody, Urine.

 

For monitoring therapeutic drug levels, order FENTS / Fentanyl, Serum.



Additional Testing Requirements


If urine creatinine is required or adulteration of the sample is suspected, the following test should also be ordered, ADULT / Adulterants Survey, Random, Urine.



Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Clean, plastic urine collection container

Submission Container/Tube: Plastic, 5-mL tube

Specimen Volume: 2 mL

Collection Instructions:

1. Collect a random urine specimen.

2. No preservative.


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Urine Refrigerated (preferred) 14 days
  Frozen  14 days
  Ambient  72 hours

Reference Values

Negative

Screening cutoff concentration: 2 ng/mL

Day(s) Performed

Monday through Saturday

Report Available

Same day/1 to 2 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

80307

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FENS Fentanyl Screen, U 59673-4

 

Result ID Test Result Name Result LOINC Value
63060 Fentanyl Screen, U 59673-4

Method Name

Immunoassay

Forms