Sign in →

Test Code LAB93778 COVID-19 Molecular/Influenza A,B Molecular

Reporting Title

COVID-19 Molecular/Influenza A,B Molecular

Performing Laboratory

OhioHealth Laboratory Services-RMH, GMC, DH, DMH, MGH, GMH, HMH, GCMH, WECC, PMC, MH, SH, BH and OMH.

Specimen Requirements

Preferred:

Nasal or nasopharyngeal specimen placed in Viral Universal Transport Media.

 

 

 

Specimen Collection

Nasopharyngeal Swab Sample:

Insert the sterile swab into either nostril, passing it into the posterior nasopharynx. Rotate swab by firmly brushing against the nasopharynx several times. Remove and place the swab into the tube containing 3 ml of viral transport medium. Break swab at the indicated break line and cap the specimen collection tube tightly.

Nasal Swab Sample:

Insert a nasal swab 1 to 1.5 cm into a nostril. Rotate the swab against the inside of the nostril for 3 seconds while applying pressure with a finger to the outside of the nostril. Repeat on the other nostril with the same swab.  Remove and place the swab into the tube containing 3 ml of viral transport medium. Break swab at the indicated break line and cap the specimen collection tube tightly.

Reference Values

Sars CoV-2: Not Detected

Influenza A: Not Detected

Influenza B: Not Detected

Day(s) Performed

Monday through Sunday; Continuously

Specimen Transport and Storage

Specimens should be tested as soon as possible after collection.  The UTM sample is stable for up to 4 hours at 18-25ºC and up to 72 hours at 2-8ºC.

Note: Specimens tested on the Roche 8800 at RMH are stable up to 48 hours at 18-25ºC 

Specimen Transport Temperature

Refrigerate: OK

Ambient: OK uo to 4 hours

Frozen: NO

Methodology

Nucleic Acid Amplification

CPT Coding

 

87636